300
Encore — Configuration Manual
Section 6 — Control Panel Configuration
Serial Clients are listed on the left side of the screen and Ethernet Clients
are listed in the middle of the screen.
•
Clicking on a button selects that Client, adds an arrow to the button,
and displays it in the
Selected Client Name
field below.
•
Clicking on the name portion of a selected button opens a text entry
window allowing the editing of the name of the selected Client.
Note
All RCL Clients must have unique names to prevent unpredictable behavior.
RCL Client names also must not begin with any form of “com.”
•
Clicking on the
IP
field of a selected Ethernet button opens a numeric
entry window allowing the setting of the IP address for the Client. This
is the address the Server will use to communicate with the Client.
Communications Indicators
Each Client button has a communications status indicator that is colored
green under the following conditions:
•
For Ethernet clients, the indicator is green if the client is connected.
•
For RCL serial clients, the indicator is green if the serial port has been
successfully opened and the client is connected. However, if the client
later becomes disconnected, this cannot be detected so the indicator
will not be turned off dynamically.
•
For NP serial clients, the indicator is green if the server has successfully
opened the port and is ready to receive and respond to the clients.
Clients may or may not be connected at the other end, however. When
a new NP serial client configuration is created, its indicator goes green
only after clicking on the
Resync Comms
button, since that is when the
port is actually opened. Otherwise, the port is opened and the indicator
will go green at the next start up of the Panel Server.
Disconnection and Notification
•
The Encore RCL Server drops automation Ethernet client applied Pro-
tects if an Ethernet client disconnects from the server due to a broken
Ethernet connection.
•
The Encore RCL Server provides a console warning message and dis-
connects any automation client that exerts excessive load on the server.
This prevents a mis-behaved automation client from adversely
affecting the rest of the Encore system. After a serial client has been dis-
connected, the RCL Server connection status indicator for the dropped
port will go red. Selecting that disconnected client and executing
Resync
Comms
reinitializes the port, and if successful its indicator goes green.
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...