90
Encore — Configuration Manual
Section 4 — Initial Encore System Setup
2.
If you have Concerto or Acappella matrices controlled by the
redundant Encore SCBs above, their equivalent internal reference
mechanisms must be turned off so they don’t conflict. Go to the web
pages of Concerto and Acappella matrices and do the following:
•
For Acappella, go to the
Reference Config
page and in the
Reference
Time Server
section disable the
Broadcast field rate time reference
option.
•
For Concerto, go to the
Reference Config
page and in the
Frame Count
Server
section disable the
Broadcast frame count
option.
Note
All
S
CBs and all controlled Matrices must have their Frame Count
S
erver set-
tings set properly for non-VITC operation synchronized Takes.
Reference count mode changes are immediate (no reset is required). Once
enabled the reference count status is reported on the screen (e.g. Client).
Redundancy Requirements and Notes
•
Each redundant Encore application pair must execute in a System Con-
troller set defined as a mirrored pair in either the same or different
System Controller frames.
•
Redundant pair System Controller Boards (SCBs) must be configured
identically regarding system configuration and executing applications
and must be executing the same revision application software.
•
All configuration tasks (except redundancy configuration) must be
done from the master.
•
The CP Server should be taken offline prior to making any changes to
redundancy parameters. The changes will come into effect only when
the CP Server is turned online again or when the CP Server or the SCB
is re-started.
•
If a CP Server is turned offline and re-started without turning it online,
the CP Server will come up in offline mode.
•
Copy Master to Mirror and Copy Mirror to Master operations can be
initiated from the OUI of the master only.
•
Copy Master to Mirror and Copy Mirror to Master operations can be
performed when either the master or the mirror or both are offline.
•
A CP Server configured as mirror should not be promoted to master
mode if the current master CP Server is online. This can be done only
after making sure that the current master CP Server is reconfigured
either as a mirror, as a standalone unit, or kept offline. This is intended
to be done when the SCB running the master CP Server is broken and
hence cannot serve the panels either temporarily or permanently.
•
If a mirror is promoted to master, the original master will come up in
offline mode when it re-starts.
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...