3. Once the drive unit is free, loosen the top screw holding the DVD drive in the front unit.
4. Pull out the DVD drive.
5. Reverse the steps above to install a replacement DVD drive.
Servicing hard disk drives
The sections given here describe various installation and replacement procedures for the hard disk
drives in each CPU/IO module. Refer to the procedure that applies to your condition.
Locating a failed hard drive
Use this procedure to locate a failed hard disk drive. A failed hard disk drive will be indicated by
an amber DISK ACCESS LED on the hard drive handle.
To verify a disk failure, do the following:
1. From
Start
, select
All Programs
,
RDR
, and click
RDR Utility
to start the RDR Utility.
2. From the tree on the left pane of the RDR Utility, select each disk and check the values of
MTBF:
Current
and
MTBF:NumberOfFaults
in the right pane.