3. Refer to the table below, if either of the values is different from the normal value, the disk has
an error.
Normal value (no error)
Description
Property name
Unknown
Mean time between hardware
failures
MTBF: HardCurrent
Unknown
Mean time between software
failures
MTBF: SoftCurrent
4. If an error is indicated, replace the hard disk drive.
Replacing failed hard drives
Follow the hard disk drive procedures in the order below to replace a failed hard disk drive. The
hard disk drive should be replaced with a new device with the server powered on.
1. Locate the failed hard disk. When a hard disk fails, the DISK ACCESS LED on the hard disk
drive’s handle turns to an amber color.
2. Remove the failed hard drive as described in the related procedure in this manual.
3. Install the new hard drive as described in the related procedure in this manual.
4. Check the following:
•
The hard disk to be installed for replacement must have the same specifications as its mirroring
hard disk.
•
Use an unsigned hard disk drive for replacement. To use the signed disk, it is necessary to
recover the duplex configuration by referring to Disk Operation in the configuration section
of this manual after formatting the disk physically.
•
Before performing physical formatting, change
Option ROM Scan Monitoring
to
Disabled
on
Server Monitoring Configuration
in the BIOS setup utility.
5. Restore the redundant configuration.
Installing a hard disk drive
Follow the procedure below to install hard disk drives that have been removed from a faulty CPU/IO
module and are being installed in the replacement module from the factory.
1. Shut down the OS. The system turns off automatically.
2. Remove the front bezel.
NOTE: When installing hard disk drives into a replacement CPU/IO module, be sure to put
the hard disk drive into the same slot that you marked on it when you removed it from the
failed CPU/IO module.
86
FT Server Instruction Manual
20131220
Servicing the FT Server
Summary of Contents for FT
Page 1: ...Fault Tolerant Server Platform FT Server Instruction Manual 071 8852 03 20131220 ...
Page 2: ......
Page 3: ...Fault Tolerant Server Platform FT Server Instruction Manual 071 8852 03 20131220 ...
Page 4: ......
Page 36: ...36 FT Server Instruction Manual 20131220 FT Server Installation Information ...
Page 42: ...5 Click OK 42 FT Server Instruction Manual 20131220 Configuring the FT Server ...
Page 90: ...90 FT Server Instruction Manual 20131220 Servicing the FT Server ...
Page 94: ...94 FT Server Instruction Manual 20131220 Trademarks and Agreements ...