GUIDE TO INSTALLATION AND OPERATION
26
| IPG-4901
4.6 Factory/Presets Panel
User Presets
The IPG-4901 has memory registers which can hold
up to 5 user-defined parameter settings.
Select
any one of the five presets using the Card
Preset Select pull-down.
Click
Load
to load the contents of the selected User
Preset into the IPG-4901. All parameter settings and
values will be replaced by the contents of the selected
User Preset.
A confirmation box will pop up to allow you to proceed
or cancel the load.
Click
Save
to store the current parameter settings
and values from the IPG-4901 into the selected User
Preset. The existing contents of the preset will be
overwritten. A confirmation box will pop up to allow
you to proceed or cancel the save.
You can edit the name assigned to each user preset.
•
Click
Edit Presets Label
to open the Presets window.
•
Double-click on a name in the Label column
•
Type a new name in the window.
•
Click OK
The text you have entered (up to 16 characters) will be appended to the label name in the selection pulldown
4.6.1 Factory
Clicking the Load Factory button will restore the card to a factory default state. Four checkboxes enable the user to
choose whether to include Card Parameters, Card Alarms, Network Settings and Presets in the restoration process
Note – Card Alarms only are reset to factory values; iControl Alarms and GSM alarms are not reset. With reference to
the Alarm Configuration panel:
Figure 4-13 Factory/Presets Panel