GUIDE TO INSTALLATION AND OPERATION
IPG-4901 |
29
Copy profile to
This section shows other IPG-4901 cards that are available on the iControl network, each identified by App server,
Densité frame and slot number, card type and firmware version.
The
Profile
column shows the same information as is shown for the current card in the Copy profile from line, i.e. one
of the following:
•
All, Current, User1, User2, User3, User4, User5
The
Select
column includes a checkbox to identify which IPG-4901 cards you wish to copy profiles into from the
current card.
•
For convenience, a
Select all
checkbox is provided in the column header
Click
Copy
to copy the selected profiles from this card into the selected other IPG-4901 cards
•
While the profile copy operation is in progress, the Transfer Status box on the right of the
Copy profile to
line will
indicate
Working
against a yellow background
•
When the profile copy operation is complete, the Transfer Status box on the right of the
Copy profile to
line will
indicate
Succeeded
against a green background
Note – the source and destination cards must have the same firmware version, so any destination cards with a
different firmware version that are shown in the
Copy profile to
list cannot be selected, and their transfer status is
always N/A on a yellow background
4.7 Alarm Config Panel
This panel allows the alarm reporting of the IPG-4901 to be configured. The panel opens in a new window when the
button is clicked, and can be resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the alarms reported by this IPG-4901 card.
•
Each alarm name includes an icon that shows its current status
•
Some alarms may be text-only and the alarm status is shown in the name and not by a status icon