B5.61
◀
RollTrack Address
This item allows the address of the selected
destination unit to be set.
RollTrack Address
RollTrack Address
0
Clear
Preset
OK
To compile/edit the text the right
▶
and left
◀
buttons adjacent to the upper text line in the menu
should be used to select the character position in
the text and the spinwheel used to select the
character.
The
◀
Clear
function blanks the selected
character.
The
◀
Preset
function loads the default address.
O.K.
▶
saves the address and returns to the main
menu.
The full
RollTrack
address has four sets of
numbers
For example: 0000:10:01*99
The first set (0000) is the network segment code
number
The second set (10) is the number identifying the
(enclosure/mainframe) unit.
The third set (01) is the slot number in the unit
The Fourth Set (362)
Each RollCall unit has a unique identification
embedded in the units’ software. In this example
362 represents an IQDMX00, 412 would represent
an IQDEC00, 161 a Mach 1 etc. Inserting this
number in the RollTrack address ensures that only
the correct type of unit (in this example an
IQDMX00) will respond to the RollTrack command;
any other unit will ignore the command.
If this number were set to 00
any type
of unit at
this location would respond to the RollTrack
command, possibly causing unpredictable results.
The unit ID of a module on the RollCall network
may
be
found
under
RollCall
Control
Panel/RollCall Listing/Unit Information
or via the
RollCall Control Panel
Help/About Current Unit
function
.
◀
RollTrack Command
RollTrack Command
RollTrack Command
0
Clear
Preset
OK
The full
RollTrack
command has two sets of
numbers
For example: 84*156
The first set (84) is the
RollTrack
command
number
Note that only command numbers 14, 15, 16 and
17 should be used for audio delay
The second set (156) is the value sent with the
RollTrack
command number.
For details of the RollCall command values for
specific units please contact your local Snell &
Wilcox agent.
◀
RollTrack Sending
This item shows when the unit is actively sending
the RollTrack command.
RollTrack Sending/Status
RollTrack Sending/Status
YES
OK
This may show:
String
A string value is always being sent.
Number
A number value is always being sent.
No
The message is not being sent.
Yes
The message is being sent.
Internal
Inconsistent behavior; please contact
Type Error your local Snell & Wilcox agent.