67
IQH4B
User Manual
POWER_USAGE=
Power Usage
OK:nnnW or
OK:mmmLU
e.g. OK:74W or
OK:72LU
WARN:nnnW or
WARN:mmmLU
e.g. WARN:144W or
WARN:167LU
Current power usage
of all cards fitted, in
Watts (W) or Load
Units (LU). This will
indicate
WARN
if
value exceeds
POWER_MAX
.
POWER_CHECK=
Power Detail Check
OK - all modules are
either reporting
power usage
successfully, or have
an entry in the
database.
WARN:REFER
MANUAL - one or
more cards are not
reporting power
usage successfully, or
do not have an entry
in the database, and
the power usage
slider on the Slots
pages (beginning
) is set to 0.0.
Reports if cards have
a known power rating
or not.
IP_BRIDGE_STATUS=
IP Bridge Status
OK:Primary
(Connected)
OK:Secondary
(Connected)
FAIL:Inactive
(Disconnected)
INFO:Primary
(Connected)
INFO:Secondary
(Connected)
INFO:Inactive
(Disconnected)
When enabled,
changes logging state
of log field
IP_BRIDGE_STATUS to
OK
or
FAIL
instead of
INFO
.
OK:Secondary
and
INFO:Secondary
are
only displayed if the
secondary IP address
is enabled and
connected.
MONITOR_CARD=
Monitor card
presence
OK:Present
FAIL:Not Fitted
Logs presence/
absence of chassis
monitor card
providing comms for
PSUs and fans.
POWER_REG_
n
_CARD
=
Power regulation card
presence
OK:Present
FAIL:Not Fitted
Logs presence/
absence of chassis
power regulation
card.
VOLTAGE_1_NAME=
Voltage rail name
Text
For IQ equipment,
these are +7.5V & -
7.5V rails.
Field Name
Field Name
Description
Valid Field Values
Usage Description
Summary of Contents for IQH4B
Page 1: ...www grassvalley com IQH4B IQRCG00 User Manual Issue 2 Revision 3 2022 06 30 ...
Page 16: ...xvi ...
Page 20: ...xviii ...
Page 80: ...78 ...