Chapter 4 Installing the Level 3 Storage System
Power on the L3 RAID chassis
Your preparations for L3 RAID storage are now complete.
Preparing K2 Storage System clients
Any devices that function as iSCSI clients to the K2 Storage System must be prepared
with the following requirements:
• One or more connections to the control network.
• A static IP address for the control network.
• For a Level 2 or 3 (non-redundant) K2 Storage System, one connection to the
media (iSCSI) network.
Additional steps that are required for Aurora Edits include the following:
• Implement Aurora Edit security features.
• Install SNFS software and K2 software.
POWER
SERVICE
K2
RAID STORAGE
!
Power Cords
(115V/2
3
0V)
Power-up Verification
DIR
a
nd
S
VP LED
s
on the RAID controller
s
a
re
b
linking green
Di
s
k Link LED i
s
s
te
a
dy ON green.
FLT
a
nd BAT LED
s
a
re OFF.
The front Power LED i
s
ON,
S
ervice LED i
s
OFF
a
fter
ab
o
u
t 5 min
u
te
s
.
Refer to the L3 RAID Instruction M
a
nu
a
l if there i
s
a
pro
b
lem.
Power LED
Disk Link
LED
Disk Link
LED
Connect power cords, and turn on power as shown.
You must power-up any RAID Expansion chassis
prior to, or at the same time as the RAID Controller
chassis. Verify power-up as shown.
Service LED
Summary of Contents for K2 BASECAMP EXPRESS
Page 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Page 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Page 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Page 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Page 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Page 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Page 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...