53
Kula
Installation Manual
Kula IP Mainframe Connections
Kula IP Mainframe Inputs/Outputs
A1 and B1 -
Primary
Inputs and
Outputs
A2 and B2 -
Secondary
Inputs and
Outputs
Inputs A1 and B1
- 1x 50GbE each Primary QSFP connection. A1 is on the
upper 'A' card, and B1 is on the lower 'B' card.
Inputs
-
18x on each Primary 50GbE input = 36x Inputs Total
SMPTE 2022-6 or VSF TR-03 (SMPTE 2110) SD/HD/1080p inputs across two
50GbE links. Each 50GbE link transports 9x SMPTE 2022-6 or VSF TR-03
(SMPTE 2110) SD/HD/1080p inputs.
Outputs A1 and B1
-
6x on each 50GbE output = 12x Outputs Total
SMPTE 2022-6 or VSF TR-03 (SMPTE 2110) SD/HD/1080p outputs across two
50GbE links. Each 50GbE link transports 3x SMPTE 2022-6 or VSF TR-03
(SMPTE 2110) SD/HD/1080p outputs.
Inputs A2 and B2
- 1x 50GbE
each Secondary QSFP connection. A2 is on the
upper 'A' card, and B2 is on the lower 'B' card.
Inputs
-
18x on each Secondary 50GbE QSFP
SMPTE 2022-6 or VSF TR-03 (SMPTE 2110) SD/HD/1080p inputs across two
50GbE links. Each 50GbE link transports 9 x SMPTE 2022-6 or VSF TR-03
(SMPTE 2110) SD/HD/1080p inputs.
Outputs A2 and B2
-
6 x on each secondary QSFP -
SMPTE 2022-6 or VSF
TR-03 (SMPTE 2110) SD/HD/1080p outputs across two 50GbE links. Each
50GbE link transports 3 x SMPTE 2022-6 or VSF TR-03 (SMPTE 2110)
SD/HD/1080p outputs.
Note:
A2 and B2 Secondary are for redundancy.
Kula IP Mainframe Input BNCs
Input BNCs
Input BNCs 4 x HD/SD/1080p (270Mbps / 1.485Gbps / 2.97Gbps). Serial digital
interface as REC601/ SMPTE/292M / SMPTE424M via BNC connectors.
Including 1 x 12G-SDI ( SMPTE 2082) single link BNC connector (silver BNC).
Kula IP Mainframe QSFP Inputs/Outputs Formats & Levels
IP Input and
Output
Signals supported over RTP stream per rear module with 2 x 50GbE QSFP
Cages. QSFP+ Optical 2 x 50G Ethernet
Conforms to IEEE 802.3ba - 100GBASE-SR4 100Gigabit over fiber.
QSFP+ direct attached copper (DAC) cable 100GBASE-CR4 100Gigabit
Ethernet over twin axial cables
Analogue HD
Reference
±300mV tri-level sync
6dB
Analogue SD
Reference
300mV sync with optional 300mV pk-pk burst
6dB
Impedance
75 ohms (except reference input).
Kula IP Mainframe Bi-Directional Inputs/Outputs
Summary of Contents for KULA
Page 1: ...Installation Manual Issue 5 Rev 1 2020 10 29 KULA PRODUCTION SWITCHER ...
Page 16: ...xvi Notices ...
Page 20: ...2 Introduction About this Manual ...
Page 40: ...22 Cabling and Connections Mainframe Connections ...
Page 50: ...32 Environment and Location Ancillary Panels ...
Page 61: ...43 Kula Installation Manual Desk Cutout Dimensions for K5P 1M E 19 Control Surface ...