Operating instructions | Managing files
4-24
parameters). The tables in the Appendix indicate the functions that are stored in the
scene file and those functions that are stored in an operator file.
4.9.1 Scene files
Four scene files are stored in the camera itself (SCAM1,SCAM2, SCAM3 and
SCAM4). Another four scene files can be stored on the camera card (SCARD1,
SCARD2, SCARD3 and SCARD4). A STANDARD scene file (preselected as either
factory or customer defined) is stored in the camera.
☞
Note
The standard customer scene file is stored via the
SECURITY
menu, not the
FILES
menu. The decision to use the factory defined file or the customer defined file as
the standard file is also made in this menu.
The
FILES
menu enables the scene files to be stored and recalled using the store
and recall entries of the menu system. If the message
NOK
is displayed, then the
old values are restored. If the camera is on-air when a scene file is recalled, then
the recalled values do not become active until the camera goes off air.
4.9.2 Operator files
The
FILES
menu also allows the recall of the operator file stored in the camera
(OCAM1) or one of the two operator files (OCARD1 and OCARD2) stored on the
camera card. These files contain information for setting up the non-video
configuration of the camera. A STANDARD operator files (factory or customer
defined) is stored in the camera.
☞
Note
The standard customer operator file is stored via the
SECURITY
menu, not the
FILES
menu. The decision to use the factory defined file or the customer defined
file as the standard file is also made in this menu.
4.9.3 Standard files
The green
STD button
(6) on the left-front side of the camera recalls the standard
scene file. This file contains standard parameters for the picture performance. A
standard operator's file can be recalled via the
FILES
menu. This file contains
parameters for the set-up of the camera.
4.9.4 Customer standard files
You can define a customer standard file for the standard scene file and for the
standard operator's file. The contents of the customer files for both these standard
files is stored via the
SECURITY
menu. The selection of a factory defined or a