4-2
Operator's Manual - LDK 5000
Location of Controls
Clea
r
Clea
r
A 1
Star 4P
ND1/4
B 2
Star 6
P
ND 1
/16
C 3
Soft fo
cus
ND 1
/64
D 4
Call
Mic
VF
Front Rear 48V
Ext
Scrip
Light
Breaker
Power on
DC in
CVBS (option)
Eng
Prog
r
Prod
Eng
Off
Prod
Ext
Mix
Front
Rear
Loc
TP
Mic 2
48V On
12V 1,5A DC Out
Ext 2
Ext 1
Power Supply
Power switch
The power switch has two positions:
On
:
Power to camera is switched on.
Off
:
Power to camera is switched off.
When you switch off the power, the access rights that were
obtained by the use of the PIN code are disabled and the
camera starts at the assigned user level when switched on
again.
Power on indicator
The power on indicator lights when power is supplied to the
camera and the camera power switch is on.
DC and Tally output socket
This socket su12Vdc (±0.25V) when the camera is
in the Triax mode (maximum current 1.5A). The socket
also provides access to an internal tally switch. When the
camera is on-air the contact of the internal relay is closed.
Circuit breaker button (BREAKER)
If excessive current flows in the camera the circuit breaker
trips and shuts off power to all the units. If this happens
check the units for faults and if necessary take corrective
action before pressing the circuit breaker button to reset
the power.
DC input socket
This socket accepts a DC supply voltage of 12V Nominal
(11V to 17V) for powering the camera in stand-alone mode
for service purposes. Maximum power consumption 23W.
CAUTION
The input voltage must not exceed 17 Vdc.
Triax cable socket
The triax cable is connected to this socket. The power
supply for the camera is normally supplied from the Base
Station via the triax cable.
The triax cable also carries all the video, audio/intercom
and control signals between the camera and the Base
Station.
1
2
4
5
6
3
1
2
3
4
5
6