Copper cabling
2 December 1999
PFC 500/E Instruction Manual
69
Copper cabling
Type: Shielded, 75
Ω
twin-axial, shield bonded to DB-9 plug
connector shell (360
°
)
FC-AL Standard, Revision 4.4 or higher
Length: 0.3 m (1 foot) min., 10 m (33 feet) max. PFC 500 to PFC500E,
30 m (99 feet) max PFC500 to Profile XP Media Platform;
< 10 m (33 feet) unequalized; > 10 m (33 feet) equalized
Standards certification and compliance
A stand-alone iDAE complies with the international environmental and safety
specifications listed below. Each iDAE will be marked to indicate such compliance
and certification as required.
Safety standards
EMI standards
Fibre Channel related standards
Standard
Description
CSA 22.2 No. 950
Safety of Information Technology Equipment
including Electrical Business Equipment.
EN 60950
Safety of Information Technology Equipment
including Electrical Business Equipment.
UL 1950
Safety of Information Technology Equipment
including Electrical Business Equipment.
Standard
Description
FCC Part 15
Class B, Radio Frequency Device Requirements
ICES-003
ClassB, Interference-Causing Equipments
Standard - Digital Apparatus
CISPR22
Class B, Limits & Methods of Measurement of
Radio Interference Characteristics of ITE
CE Mark
European EMC Directive & Low Voltage Directive
Requirements
VCCI
Class B, Voluntary Control Council for Interference
AS/NZS 3548
Class B, Electromagnetic Interference - Limits &
Methods of Measurement of ITE
CNS13438
BCIQ EMC Requirements
Standard
Description
Fibre Channel
Physical and signaling interface, FC-PH, Revision
4.4
Fibre Channel
Arbitrated Loop (FC-AL), Revision 4.5
Fibre Channel
Private Loop Direct Attach (PLDA), Revision 1.10
SCSI III
SCSI Enclosure Services (SES), Revision 8a