Input Format
Input format select switch S100 must be set to conform to the
input key signal format being used.
lists the format
selections.
Position 6 should be used if the key signal does not have setup.
If the input has setup present, Position 7 should be used.
Black Level Control
If Input Format Switch Position 7 is used, the black level control
will be operational. This control compensates for possible
incorrect setup level on the video input.
The output Y channel black level will be held fixed by a digital
clamp when using Input Format Position 6, and the control will
not function.
Table 1. Format Selection
Input Format Select Switch Positions
6 = No Setup
7 = Setup