21
Module Alignment
Free Run Frequency Adjustment
To adjust the Free Fun Frequency, follow the steps listed below:
1.
Place the module on an extender board. (Allow 5 minutes to
reach operating temperature.)
2.
Remove video input signal.
3.
Set Jumper JP103 in the G INPUT position (if it is not already
in that position). Refer to
4.
Observe frequency at test connector P500, pin 12, (end pin
near TP18) with frequency counter.
5.
Adjust R960 for a frequency of 13.5MHz, ±25Hz.
6.
When calibration is complete, set JP103 in the previous
position, if it was moved.
Figure 9. JP103 Jumper Settings
OR
JP103
EXT
REF
G
INPUT
JP103
EXT
REF
G
INPUT
8301A-K