93
UCP
-
3901
User Manual
SLOT_START=
Logs the slot in the rack where the card is located.
POWER_USAGE=
Logs the power usage in watts and PR Units.
Note
: this cannot be deselected.
TEMP
_N_
CELSIUS=
Logs the temperature status of the FPGA in Celcius.
Note
: this cannot be deselected.
TEMP_
N
_NAME=
Logs the Temperature measurement name.
REFERENCE_
N
_SOURCE=
Logs the time reference source.
REFERENCE_
N
_STATE=
Logs the time reference value. Valid values are:
•
OK:Locked
•
OK:Input
•
WARN:Freerun
•
WARN:CrossLock
TIMESYNC_
N
_MODE=
Logs the time sync mode value. Valid values are:
•
Free running
: Card is using its own clock with no
reference to any other source.
•
PTP Multicast
: Card is synchronizing to a PTP
grandmaster clock using multicast network
messages.
•
PTP Unicast
: As PTP Multicast but using the delay
request. Reply messages are unicast to minimize
network traffic.
•
NTP
: Card clock is synchronized to an NTP clock.
Generally less precise than PTP.
TIMESYNC_
N
_NETWORK=
Logs the network port currently being used for
synchronization for UCP
-
3901 cards, dependent on
the choice of interfaces made on the Time
Configuration page. If PTP and multiple interfaces are
enabled, the PTP synchronization will switch ports if
it doesn't see regular sync messages on the port.
TIMESYNC_
N
_CLOCK_ID=
Logs the identification number of PTP clock being
used for synchronization. This is not necessarily the
grandmaster clock identity, as there can be
intermediate clocks between the grandmaster and
the card, depending on network configuration.
TIMESYNC_
N
_CLOCK_STATE=
Logs the time sync value. Valid values are:
•
Free running
: Card is not being synchronized.
•
No Lock
: PTP being used but clocks haven't
synchronized /- 1mS.
•
Locked
: PTP being used and clocks are within the
accepted range.
•
NTP
: Card using NTP to synchronize.
Log Field Parameter
Description
Summary of Contents for UCP-3901
Page 1: ...User Manual 13 03084 010 M00 AB 2020 10 27 UCP 3901 UNIFIED COMPUTE PROCESSOR FOR DENSITÉ ...
Page 18: ...18 Introduction Supported SFP28 Cartridges ...
Page 32: ...32 UCP 3901 Card Installation and Operation Remote control using RollCall ...
Page 36: ...36 Connections and Cabling Cabling to Support SMPTE ST 2022 7 with a UCP 3901 ...
Page 122: ...122 Essence Processing SDC SFP Configuration ...
Page 202: ...202 Maintenance Troubleshooting Keep Fiber Connections Clean ...