Where N is the input or Ethernet port number
.
To identify SFP 1 / 2, see
FAN_STATUS
Logs the card’s cooling fan health.
•
OK:
The card’s fan is operating normally.
•
FAIL:
The card’s fan is not spinning, or is spinning
too slowly, or the fan cable is disconnected.
Urgent maintenance procedures must be
considered: If this alarm has been raised, the fan
on the UCP
-
3901 card may have to be replaced.
See
Cooling Fan Operational Assessment
DENSITE_CONTROLLER_STATUS
Reports the connection status of the Densité frame’s
controller card to the UCP
-
3901 card.
OK:
The UCP
-
3901 card has successfully connected to
the Densité frame’s controller.
Not Connected:
The UCP
-
3901 card did not connect
to the Densité frame’s controller or the UCP
-
3901
card has lost connection to the Densité frame’s
controller.
DENSITE_CONTROLLER_IP_ADDR Reports the IP Address of the Densité frame’s
controller card. If the IP address is 0.0.0.0, then the
UCP
-
3901 card has not yet received the IP address
from the frame’s controller.
DENSITE_FRAME_SLOT
This is the slot number in which the UCP
-
3901 card is
located within the Densité Frame.
Log Field Parameter
Description
Summary of Contents for UCP-3901
Page 1: ...User Manual 13 03084 010 M00 AB 2020 10 27 UCP 3901 UNIFIED COMPUTE PROCESSOR FOR DENSITÉ ...
Page 18: ...18 Introduction Supported SFP28 Cartridges ...
Page 32: ...32 UCP 3901 Card Installation and Operation Remote control using RollCall ...
Page 36: ...36 Connections and Cabling Cabling to Support SMPTE ST 2022 7 with a UCP 3901 ...
Page 122: ...122 Essence Processing SDC SFP Configuration ...
Page 202: ...202 Maintenance Troubleshooting Keep Fiber Connections Clean ...