Zodiak Installation and Service Manual
129
Tally Configuration
Assignment of Tally Relays to Sources:
Touch
Eng Setup
,
Tally, Relay Assign
(the Relay Assign button is in the Function
pane) to access the Tally Relay Assignments menu (
Figure 89. Tally Relay Assign Menu
The default tally calculator is the On Air calculator, and for the standard 32
relays to tally the first 32 sources (1-32).
In the Tally Relay Source Assignment menu is a selector for the Calculator,
a Relay list, and a Sources list. In addition, there are Quick Assign buttons
and a Test Relay control.
Touch the Tally Calculator to be assigned to the relay group. All buttons
toggle on and off independently, so you can select more than one calculator
to be applied to the relay group. The text in the buttons is formatted such
that the upper line shows the Calculator Identification and the bottom line
shows the Calculator Name.
Touch a numbered Relay button from the list, and then assign a Source to
that Relay from the list of Sources. The Source button displays the Engi-
neering ID, and the user defined Engineering name (if an Engineering
name has been entered in the Source Definition menu). Tally relays map to
Engineering Sources, not Logical Sources, to ensure tally is consistent
regardless of source patching. The Source name will display in the non-