130
Zodiak Installation and Service Manual
Section 3 — Configuration
editable data box next to the Relay. Relays already assigned will automati-
cally show their assigned Source. If a relay is unassigned or the
None
button
is selected for that Relay,
---
is displayed.
The four
Quick Assign
buttons will assign the 32 relays in the group respec-
tively to sources 1-32, 33-64, 65-96, or 97-128.
CAUTION
When a Quick Assign button is pressed it will immediately assign the relays.
To reassign the relays requires each button to be individually selected and
reassigned one at a time.
The Test Relay button when toggled On causes the selected relay to flash
on and off at a rate of 1 Hz as an aid in setup and troubleshooting. The test
flash mode persists as long as the
Test Relay
button is on and is automatically
shut off when the Tally menu is exited.