146
Zodiak Installation and Service Manual
Section 4 — Maintenance
Menu Panel Maintenance
The Menu panel requires no routine maintenance. Calibration procedures
for the touch screen are available through Windows 2000 on the Menu
panel (see
Touch Screen Calibration on page 136
).
Cleaning
Clean the Menu panel and touch screen with household glass cleaner and
a non-abrasive towels. Always dampen the towel and then clean the touch
screen. Do not spray cleaner directly on the Menu panel or touch screen.
The Menu panel enclosure pulls air through a top vent and expels it out the
right side. Make sure these areas are not blocked for air intake and exhaust.
Video Processor Frame Maintenance
CAUTION
Do not operate the Video Processor frame with its door open for an extended
period of time. Failure to observe this precaution may result in improper air
flow and cause components to overheat.
Air Filter Cleaning
The Video Processor frame contains a removable air filter that reduces the
accumulation of dust on the circuit boards. The air filter should be removed
and cleaned periodically.
To clean the frame air filter:
1.
Open the door of the Video Processor frame and locate the air filter
(
).
2.
Remove the filter by pulling the white plastic handle at the front center
of the filter. Pull the filter out slowly, making sure the metal netting on
the right of the filter does not catch on the frame.
3.
Vacuum the filter and/or wash it in a warm water soap (not detergent)
solution.
4.
Rinse the filter thoroughly with fresh water, and air dry completely.
5.
When the filter is completely dry, reinstall it into the frame with the
metal netting to the right. Close the door of the frame.