172
Zodiak Installation and Service Manual
Section 5 — Troubleshooting and Diagnostics
Figure 124. Drain NV RAM Screen
c.
Communications must exist between the Menu panel and the Video
Processor frame, where NV RAM resides. Touch
Ping
to test the
connection. If unsuccessful, the communications problem must be
corrected before proceeding (it could be an incorrect IP address).
d.
After a successful Ping, check the
Drain NV RAM
check box and touch
Start
, and confirm the dialog box by touching
OK
.
e.
A progress bar will be displayed. When done, touch
OK
.
3.
Reset the Video Processor frame again, using the operation boot dial
setting.
a.
Turn the Video Processor frame Control Processor/Still Store/DSK
module
S2
boot dial switch to position
0
.
b.
Press the
Reset
button and allow at least 30 seconds for the system
to reboot.
4.
Once system communication is resumed, restore your backup files in
the following order:
a.
Reload your backup Engineering Setup file and make sure it is
correct by, for example, checking that the proper source names
appear in the Eng Setups Sources menu.
b.
Load a Suite Profile, and check that the Suite Preferences settings
are correct.
c.
Load a User Profile and check that the User Preferences settings are
correct.
d.
Load a bin of E-MEMs and run them to check that they operate
correctly.
e.
Load Source Memory and test their defaults.