198
Zodiak Installation and Service Manual
Section 5 — Troubleshooting and Diagnostics
Lever Arm and Joystick Calibration
The Main panel lever arms and joystick can be calibrated from the Main
panel.
1.
Open the Main panel to access the Boot Switch and
Rt Panel Reset
(Main
panel)
button (refer to
position 9 (one click to the right) then reset the control panel.
After about 30 seconds, the panel will come up in a calibration mode
which will be reported in the M/E 1 E-MEM display as
Main Menu Select
(not shown). Use the M/E 2 E-MEM display and buttons to step
through the calibration process (see
). During the procedure,
the Master E-MEM display in the lower right corner of the panel will
show the current minimum and maximum values for the selected lever
arm or joystick positions.
2.
To enter calibration mode, push the
8
button under
Calib
on the M/E 2
E-MEM keypad as shown in
will change to report
Calibration Mode
(not shown).
Figure 140. M/E 2 Display in Calibration Mode
3.
The display will change to bring up the first calibration routine, M/E 3
(PGM/PST for 2.5-M/E systems), as shown in
Undo
Learn
Lock
Bank
1
2
3
4
5
6
7
8
9
0
Run
Seq
Bank
0
Effects
Dis
Bank
1
Tran
Rate
Enter
E-MEM
IP Calib Exit
8125_00_22_r0
M/E 2 E–MEM Keypad