Zodiak Installation and Service Manual
229
Appendix
A
Speci
Þ
cations
Table 25. Zodiak System Specifications
Power
Video Processor Frame
Power Supply
100-125 VAC or 200-250 VAC autorange, 50-60 Hz power factor corrected
Power Consumption
2.5-M/E: 300 W (typical)
3-M/E: 400 W (typical)
Main Panel
Power Supply
100-125 VAC or 200-250 VAC autorange, 50-60 Hz power factor corrected
Power Consumption
150 W (typical)
Environmental
Temperature Range
Video Processor
Frame, Menu Panel
Specification
1
: 68º to 86º F (20º to 30º C)
Operational
2
: 32º to 104º F (0º to 40º C)
Main Panel
Specification
1
: 68º to 86º F (20º to 30º C)
Operational
2
: 32º to 95º F (0º to 35º C)
Relative Humidity
Up to 95% (non-condensing)
Mechanical Stress
ASTM D 4728, Fig. X1.1, Table X1.1, Truck Profile.
Serial Digital Video Inputs
Number
64 non-looping
Type of Connectors
75 ohm BNC, (SMPTE 259M)
Nominal Amplitude
800 mV peak-to-peak terminated
Return Loss
> 15 dB, 5 MHz to 270 MHz
Channel Coding
Conforms to SMPTE RP-259M
Ancillary Data
Passed from A background to program outputs
Input Impedance
75 ohm, self terminating
Autotiming Range
± 14 microseconds
Maximum Cable Length Equalized
(Belden 8281 type cable)
738 ft. (225 m)
Number of Bits
10
Serial Digital Video Outputs
Number
26 outputs (3-M/E), 2 BNCs per output (52 BNCs)
Type of Connectors
75 ohm BNC, self terminating (SMPTE 259M)
Amplitude
800 mV peak-to-peak across 75 ohm ± 10% (SMPTE 259M)
Return Loss
> 15 dB, 5 MHz to 270 MHz
Rise and Fall Times (between 20%
and 80% amplitude points)
Between 400 picosecond and 1.5 nanosecond across 75 ohm termination
Timing Jitter
0.2 UI (SMPTE RP184-1996 method)
Channel Coding
Conforms to SMPTE RP-259M