50
Zodiak Installation and Service Manual
Section 2 — Installation
Joystick Override
A user fabricated cable, external switch, and a 15-pin D connector are
required to implement camera joystick override. Use shielded cable
and connect the shield to the metal connector shell when fabricating the
joystick override cable. Refer to
for connector wiring.
Joystick override programming is done in the Button Mapping menu
accessed by touching
Daily Setups
,
User Prefs
,
Button Mapping
,
Remote Panel
in the Zodiak Menu application. Refer to
Figure 30. KAL-32AUX Joystick Override Connector Cable Wiring
LAN
The 32-Crosspoint Remote Aux panels employ Ethernet network con-
figuration. Refer to
Ethernet Switches and Hubs on page 74
for informa-
tion on system topography.
Each 32-Crosspoint Remote Aux panel must have a unique IP address
to place it on the Menu (Facility) LAN. To set the IP address, refer to
Remote Aux Panel Configuration on page 115
.
Common
0
619_04_62_r3
1
2
3
4
6
7
8
5
9
10
11
12
13
15
14
Pin 1
Pin 15
Pin 9
D-15 Male
Joystick Override
Connector
(wiring side)
Pin 8
Momentary Contact Switches