Section 5 — Troubleshooting and Diagnostics
No DC Power to Zodiak Component
The Zodiak control surface, which includes the Main and Menu panels,
and the Video Processor frame are powered by completely separate power
sources as described in this section. DC power can be interrupted or termi-
nated to any Zodiak component by blown fuses, defective or loose cabling,
or, in the case of the Video Processor frame, high temperature thermal shut-
down.
DC power to each Zodiak component in the system is clearly indicated on
every module or panel board. Use the block diagram in
bleshoot loss of DC power to any component in the system.
Figure 134. Troubleshooting No Power to Zodiak Component
YES
NO
Contact Customer
Support
NO
No DC power to
control surface
or component
Power
Restored?
Temperature
normal?
Frame fans are
running?
(
No DC Power to Zodiak Component
NO
YES
Check for blown
fuses
No DC power to
Video Processor
frame component
Resolved
YES
No power to Frame
due to thermal
shutdown
Check power
supply status
(
Power
Restored?
Resolved
Check cabling
for loose
connections
Power Restored?
Allow frame to cool
until power
is restored
NO
YES
Resolved
Replace Fan
module
Check air intake
and exhaust is
sufficient
)
YES
Check module
status indicators
NO
NO
Power Restored?
YES
Replace module