8

Adjustment of the damping system

Please adjust the damping system by means of
the set screw:

turning clockwise = slower closing
turning anticlockwise  = faster closing

Attention! Do not pull out the damper. Otherwise
the product will become damaged.

After aligning the flaps and adjusting the
damping system, please mount the cover
caps.

Adjusting the Kinvaro T-65 to the flap weight

Flaps can be opened to a maximum angle of 100 degrees
with the flap fitting Kinvaro T-65. With the correct spring
adjustment, the flap stays open in all positions from an ope-
ning angle of about 45 degrees, so that you can choose the
opening angle and the reach which is
optimal for you.

Adjusting the spring tension:

turning clockwise = increase spring tension
turning anticlockwise = decrease spring tension 
(The adjustment carried out at the two fittings must be even.)

88

GB

Adjustment of Kinvaro T-65

Height adjustment of the flap

The height adjustment of the flap can be done by oblong
holes at the fixing bracket:

1. Open the screws
2. Adjust the height (± 3 mm)
3. Tighten screws again

After completing the adjustment, attach the 
locking screw.

adjusting screw

adjusting screw for damping system

KB-65-D_Einbau_Grass.qxd  22.07.2009  13:11 Uhr  Seite 8

Summary of Contents for Kinvaro T-65

Page 1: ...l Werke Black spring Cabinet height in mm Flap weight incl handle in kg Flap width in mm with 0 45 kg dm3 e g pine with 0 65 kg dm3 e g chipboard with 0 85 kg dm3 e g MDF with small with bar with small with bar with small with bar handle handle handle handle handle handle yellow spring mounted one sided up to flap width of 600 mm spring must be mounted left side 250 0 9 2 1 400 600 300 550 300 600...

Page 2: ...nel Right hand side panel mirror image buffer thickness 2 mm Opening angle 100 The drilling pattern has to be exactly observed top panel side panel These drilling holes can be used optionally for the attachment of the fitting flap Attachment at side panel 4 x Countersunk Euro screws ...

Page 3: ...top no minimum gap required no minimum gap required Flap indicated 38 top panel thickness overlay top 54 top panel thickness overlay top drilling holes for securing screw The drilling pattern has to be observed exactly top panel side panel Flap Attention Assemble the fitting only in open condition Drilling holes for wooden flap and for wide aluminium frame flap min 45 mm Drilling holes for 19 mm a...

Page 4: ...ct spring adjustment the flap stays open in all positions from an ope ning angle of about 45 degrees so that you can choose the opening angle and the reach which is optimal for you Adjusting the spring tension turning clockwise increase spring tension turning anticlockwise decrease spring tension The adjustment carried out at the two fittings must be even 8 8 GB Adjustment of Kinvaro T 65 Height a...