First contact
L-SOLUTION 100 Ex Fibre machine
. 11
1 label
:
On the LASER source. Not visible under normal operating conditions.
This LASER is manufactured by GRAVOTECH MARKING SAS
56 Avenue Jean JAURES -10601 La Chapelle St Luc - FRANCE.
It is designed for use only as a component in a GRAVOGRAPH LASER
system.
This LASER is a class 4 device and does not comply with U.S. code 21
CF subchapter J, or European standard EN 60825-1.
1 label
:
On the outside of the door. Visible from the outside under normal operating conditions with the door closed.
CAUTION LASER RADIATION.
Do not stare into beam.
Wavelength : 630-680 nm (25 10-9 - 27 10-9 inch) - Max. output :1mW.
Class 2 LASER product.
1 label
:
On the outside of the door. Visible from the outside under normal operating conditions with the door closed.
WARNING.
This LASER system contains a class 4 LASER in a class 1 enclosure.
It has been classified as class 2 due to the presence of a visible LASER
diode.
1 label
:
On the outside of the door. Visible from the outside under normal operating conditions with the door closed.
WARNING.
Never operate the LASER system without constant supervision.
Exposure to the LASER beam may cause ignition of combustible
materials which can cause severe damage to the equipment.
Toxic fumes/particles may be emitted by this machine.
1 label
:
On the outside of the door. Visible from the outside under normal operating conditions with the door closed.
CAUTION - Invisible class 4 LASER radiation if open and the lock
is disabled. Avoid exposing the skin or eyes to direct or diffuse
radiation.
2 labels
:
Inside the LASER system, on the machine protective casing on the left and on the right of the Y-Rails. Visible from
the outside under normal operating conditions with the door opened.
CAUTION.
Invisible and visible class 4 LASER radiation when opened. Avoid
eye or skin exposure to direct or scattered radiation.
2 labels
:
Inside the LASER system, on the machine frame on the left and on the right of the Y-Rails.
This label must not be visible under normal operating conditions
(machine with casing).
CAUTION.
LASER radiation. Avoid all skin exposure to direct or scattered
radiation.
Class 4 LASER product / Pulsed Fiber Laser / Wavelength : 1064 nm /
P
av
= 20 W / P
peak
: <10kW / FWHM pulse>100 ns.
LASER Safety