L-SOLUTION 100 Ex Fibre machine
. 16
First contact
Ambient room temperature MUST be between 50 and 95 degrees F (10 and
35 degrees C).
• If transporting the LASER system from a very cold or very hot environment to the proper operating environment, the
LASER system must be allowed time to adjust to the ambient temperature.
• Normal lighting is sufficient to use the machine. A lamp (J7) lights the engraving zone.
• Clear the work surface so that you can
- easily and quickly access all external parts of the machine,
- quickly access, in case of necessity, the main stop button
(L)
on the engraving table
(pict. 1)
,
- make sure that all moving parts of the machine have enough room to move freely,
- place the computer within 10 feet (3m) of the machine, if planning to connect the LASER engraving system
to a computer through the parallel port (the maximum recommended parallel cable length is 10 feet (3m)).
- avoid any accidental unplugging of the cables.
The connectors screws must be very tight to avoid accidental disconnection of the cables
while the machine is turned on as this could permanently damage the electronic cards.
• If connecting an additional LASER system or other printer to the same computer, we recommend the installation of an
additional parallel port into the computer.
DO NOT
use a manual A/B type switch box. This creates electrical noise
which can cause an engraving problem or damage the LASER system and/or the computer’s electronics.
• Protect your Gravograph equipment against:
- Moisture (rain, snow, condensation, etc.),
- Heat (direct sunlight, heating, etc.),
- Sudden changes in temperature,
- Dust (exhaust pipe, sand-blasting or sandpapering systems),
- Liquid splashes, spillages on the electronic rack, cables and connections, and any other part of the machine;
unless recommended by GRAVOTECH MARKING SAS (e.g. lubrication),
- Vibrations,
- Electric or electronic radiation.
The electrical plug acts as a sectioning device. it is therefore important that you set up
the machine in order to always have easy access to the power cable.
Installation