background image

795-92155 

01/23/14 

Graymills Corporation – 3705 N. Lincoln Ave. / Chicago, IL 60613 – Phone: 773.477.4100  Fax: 773.477.8673 – 

www.graymills.com

 

 2 

 

 

 

The unit has been factory set to maintain an optimum 
temperature for the microbes.  Do NOT attempt to 
change thermostat setting. 

 

This is a heated system. Always use caution when 
first putting hand under liquid stream to prevent injury 
from heated solution. If the liquid feels uncomfortably 
hot, discontinue use, unplug machine and call 
Graymills Customer Service. 

 

Failure to keep proper liquid level will result in 
burning out the pump and heater coil, creating a 
potential fire hazard. To help prevent this, this unit is 
equipped with a low liquid level device which will shut 
off the pump and heater. If solution stops circulating 
and the red “RESET” light becomes illuminated, 
immediately turn off and unplug unit.  For instructions 
on filling the reservoir, please see “INSTALLATION 
AND OPERATION” steps 6 through 9.  

BIO436R Only 

 

After extended use, the gas-spring used to assist in 
opening and closing the lid may lose its ability to keep 
the lid open.  At the first sign of this, replace the gas-
spring immediately. 

 

Automatic Safety Cover.  Since certain soils may be 
combustible, e.g., oils, greases, this unit is equipped 
with a fusible safety link cover mechanism designed 
to support the open cover at a slightly forward angle.  
In the event of a fire, the fusible link will melt at 165ºF 
permitting the cover to slam shut, limiting oxygen 
supply to the fire. 

 

Do not leave the unit unattended with parts in the tank 
which would prevent the cover from closing 
completely in the event of a fire.  Keep cover closed 
when unit is not in use.  If the fusible link breaks, do 
not operate the unit until a replacement link is 
installed. 

 

 

 

DO NOT leave the unit disconnected without power for 
extended periods of time (overnight or weekends).  
This will cause the microbes to go dormant.  This will 
adversely affect the bioremediation process.  If 
microbes do not reactivate after operating 
temperature has been reached, a new BIO-POUCH 
should be added. 

 

If unit is to be unused, but not unplugged or turned 
off, for extended periods (overnight and weekends), it 
may be necessary to top-off tank to the 30-gallon mark 
with pre-blended Super Biotene

TM

 cleaning solution to 

prevent the machine from shutting down due to low 
liquid levels. 

 
 

 

POWER SUPPLY, WIRING AND 
GROUNDING 

 

 

Failure to permanently ground the unit and controls 
before connecting to electrical power can cause 
shock, burns or death. 

 

Install ground and wiring according to local and 
national electrical code requirements. 

 

Install a fused disconnect switch on all power legs 
near the unit 

 

Disconnect and lockout electrical supply before 
installing or servicing unit. 

 

Unit must be properly grounded to prevent electric 
shock hazard. Connect only to three-prong outlet. 
Should cord become cracked, frayed or damaged in 
any way, it should be repaired/replaced immediately 
by a qualified electrician. Never use an extension 
cord.  (See Spare Parts List) 

 

The full-load amperage draw for this machine is 12 
amps. 

 

USE OF INDUSTRIAL CLEANING 
SOLUTIONS 

 

 

Always wear the recommended safety apparel and 
glasses. 

 

Adequate ventilation should be provided when 
operating this unit. 

 

When making an initial batch of cleaning solution or 
when adding compound, follow cleaning solution’s  
directions exactly.  

 

Industrial cleaning solutions may be irritating to some 
individuals. Be certain to consult the MSDS for the 
cleaning solution you are using before filling or using 
parts washer.   

 

If splashed in the eyes, follow cleaning solution MSDS 
instructions. 

 

If cleaning solution is splashed on clothing, remove 
promptly and thoroughly wash any body areas which 
have been in contact with solution. DO NOT permit 
saturated clothing to remain in contact with skin. 
Consult cleaning solution’s MSDS instructions. 

 

Clean up fluid spills immediately. Super Biotene

TM 

can 

create a slippery surface.  Also, the microbes 
metabolize organic materials and could damage floor 
coverings or painted surfaces.

 

 

 

Graymills strongly recommends that federal, state and 
local authorities be consulted before proceeding with 
discarding and handling of used materials.  Graymills 
Corporation accepts no responsibility for user’s 
failure to comply with regulations.

 

 

For best results, Graymills’ recommends using only 
Super Biotene

TM

 550 (concentrate) or Super Biotene

TM

 

660 (pre-blended). 

Summary of Contents for BIOMATIC BIO436R-A

Page 1: ...result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury CAUTION without the safety ale...

Page 2: ...nplugged or turned off for extended periods overnight and weekends it may be necessary to top off tank to the 30 gallon mark with pre blended Super Biotene TM cleaning solution to prevent the machine...

Page 3: ...xtinguish 14 The amber HEAT light indicates power to the heater 15 If cleaning solution is not at the appropriate temperature and heat is required you should hear the thermostat engage with a CLICK an...

Page 4: ...n of this replace the gas spring immediately Order part number 765 09631 RECOMMENDED ANNUAL MAINTENANCE Graymills recommends that the entire system be inspected and cleaned annually To perform this ma...

Page 5: ...472 9645 Heater coil dirty Clean heater coil see Recommended Maintenance Red RESET Light ON Machine needs to be reset Toggle RESET switch Low solution level Add cleaning solution Float sensor or cont...

Page 6: ...Cord and Plug 777 04152 Relay 782 92066 Relay Socket 782 92126 Rubber Condensation Guard 744 37878 Polyurethane Foam Filter 742 90883 3 8 Trim Bulb 603 37983 15 Tank 727 37995 GRAY 16 Drum 727 37883...

Page 7: ...OTHER WARRANTIES WHETHER ORAL WRITTEN EXPRESSED IMPLIED OR STATUTORY GRAYMILLS CORPORATION MAKES NO OTHER WARRANTY OF ANY KIND EXPRESS OR IMPLIED ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS...

Reviews: