795-94048
7 of 49
12/15/21
Air Motor (GAM) Characteristics
There is no pilot light or switch. The air connection is on the side of the tank with the valve. Minimum
60PSI air supply required with motor set at 1725RPM to have full pump performance.
Liquid Capacities
The liquid capacity of your PrintClean is as indicated below:
Model
Maximum
Minimum
354, 554
40 gals
20 gals
654
54.5 gals
28 gals
854
81.5 gals
49 gals
954, 974
109.5 gals
39.5 gals
Weight Limitations
The maximum weights which can be placed on the tank bottom and work shelves of your PrintClean are
indicated below:
Model
Bottom
Shelves
354, 554, 854
500 lbs.
150 lbs.
954, 974
750 lbs.
200 lbs.
INSTALLATION AND OPERATION
The work area should be well ventilated.
Provide adequate lighting in the work area to allow observation of the cleaning process and the floor
area around the machine. Be sure to allow adequate room to bring work to and from the machine.
Provide sufficient clearance around the machine for fluid changeovers and servicing.
Site Preparation
Before installing, careful consideration should be given to the place of operation. Place unit on a
smooth, level surface. To the extent possible avoid installing machine in areas subject to high forklift
traffic. Reasonable precautions shall be taken to avoid damaging the legs and tank walls.
Installation Procedure
The PrintClean is very easily put into operation. After removing it from its shipping carton, unpack any
trays and accessory components from inside the tank. Assemble the handle to the cover, and install
any parts shelfs (this will ensure freeboard compliance). Check to be sure drain plug is tightened, fill with
the desired amount of an appropriate cleaning fluid (see Liquid Capacities, above) and insert the 3-
prong plug into the proper receptacle (see electrical specifications above). If using an air motor, attach
airline hose to valve on side of unit and the unit is ready for use.
Before operating your PrintClean, read the following descriptions of its features and benefits to
maximize efficiency and longevity from your unit.
Automatic Safety Cover
Open the automatic Safety Cover (FIGURE 1 (A)) on your PrintClean and you will notice that it lifts
simply and easily with one hand. There is nothing to connect or disconnect to open or close the cover.