TP-183P User Manual
The Control Panel 3-6
Scale Length
Scale Width
to adjust the scale of media length and width that may
cause by the thickness of the media.
The Denominator is the actual length, and the Numerator
is the ideal length measured from the resultant.
For example, cutting a line with 500.0 mm length. The
procedure as followng:
1. Press the [LEFT ARROW] to choose the Numerator and
select 500.0 mm,
2. Plot the length by sending a graph file,
3. Measure the length then use the [RIGHT ARROW] key
to choose the Denominator, then
4. Press [UP ARROW /DOWN ARROW] to change the
values of the actual length.
USB Printer
Type
To select USB Mode from the LCM panel. Two USB modes
are available: GCC USB Mode and Common USB Mode.
GCC USB Mode: For 32 bit driver
[Windows XP/2000/ 7 /Vista]
Common USB Mode: Both for 32 bit & 64 bit driver
[Windows XP/7/Vista]
Common
USB Mode