4
• IMPORTANT:
All electrical installation work must be performed by a qualified electrician and must conform
to local codes
• Check to see if the proper sized GFCI is installed.
• Be sure the GFCI is rated for more amperage than the system will draw.
• For a 240V system, the GFCI must include a load neutral out.
• NOTE: If the white load neutral wire is routed from the GFCI neutral bar directly to TB1 in the system box,
then the GFCI will trip when a 120V device is activated. This is the most common reason if your hot tub is
tripping immediately.
• If the wiring is correct and the GFCI will not reset, then unplug the heater and try to reset the GFCI.
• If the GFCI trips again, then unplug the pump and reset the GFCI. If the GFCI continues to trip, then do the same procedure
for the ozone generator.
• If the GFCI stops tripping after you unplugged one of the spa’s components, turn off the power to the spa then plug in
each component except the one that tripped the GFCI.
• Power up the system. If the GFCI no longer trips, then you have correctly identified the problem.
• Repair or replace the component as instructed by the spa manufacturer.
• If everything looks to be in perfect working order, then the GFCI may be defective.
Do
NOT
proceed with installing your hot tub in freezing temperatures! In colder temperatures please make sure
to place a space heater inside the cabinet immediately after delivery for 24 to 48 hours before installation to
prevent startup issues.
A licensed electrician can install the wiring by drilling a hole into any panel and terminating the connection at
the control pack.
All hot tubs must be placed on a proper base that is reinforced for the weight of the hot tub, water and people
who may be within the hot tub at any given time. This base must be flat and come in contact with the entire
base of the spa. We recommend a base that can support at least 150 pounds per square foot such as a 4-6
inches poured concrete pad.
WINTER INSTALL
LICENSED ELECTRICIAN
PROPER SPA BASE
INSTALLATION
GFCI TROUBLESHOOTING (240V ONLY)
IF CORRECT WIRING IS VERIFIED
Keep in mind that the majority of 240V GFCI tripping problems can attribute to incorrect wiring.
GFCI troubleshooting usually finds the problem
REFER TO DIAGRAM ON NEXT PAGE
WARNING: THE OWNER SHOULD TEST AND RESET THE
GFCI ON A REGULAR BASIS TO VERIFY ITS FUNCTION
Lay your cover onto your hot tub then line up locking straps and secure with mounting hardware. Use the lock
and key clasps to secure your cover in place. Always lock your cover when the hot tub is unattended.
Do
NOT
walk or sit on the spa cover.
ATTACH SPA COVER