Row-Pro™ Air Pressure Gauge
Row-Pro™ is designed to run at 150 psi. When the psi
drops to 135 the compressor engages and builds back
up to 150 psi. Duty cycle varies based on air usage.
Check for Air Leaks
Before going to the field check for air leaks.
1. Turn the compressor on to pressure up the primary
system until it automatically shuts off. If the system
loses pressure, check for leaks.
2. Use the Leak Test mode to cycle through the
sections and check for leaks.
Row-Pro™ Adjustments
Load Cell Reading
These readings are displayed and adjusted from the
IntelliAg
®
seed monitor console.
Control Mode:
Auto
is the normal running mode.
Manual
is used to control the valves only when the
operator touches the increase or decrease icon on the
work screen.
Figure 166
Air Pressure Gauge
32098
Figure 167
IntelliAg
®
Screen