58
5.3.2 Heat Exchanger of Outdoor Unit
Conduct cleaning for the heat exchanger of outdoor unit
periodically, clean it once at least in every two months. Clean the dust
and sundries on the surface of the heat exchanger with dust collector
and nylon brush, if there’s compressed air source; use the compressed
air to blow the dust on the surface of the heat exchanger. Don’t use tap
water for cleaning.
5.3.3 Drainage Pipe
Periodically check if the drainage pipe is blocked to smooth the
condensate water.
5.3.4 Notices at the Beginning of the Using Season
(1) Check if the air inlet/outlet of indoor/outdoor unit is blocked;
(2) Check if the ground connection is reliable;
(3) Check if the battery of remote controller is replaced;
(4) Check if the air filter screen is properly installed;
(5) If starting up again after long-term shut down, preset the power
switch of air conditioner to “ON” status before 8h of operation,
to preheat the crankcase of outdoor compressor;
(6) Check if the installation of outdoor unit is firm, if not, please
contact with Gree appointed maintenance center.
5.3.5 Maintenance at the End of the Using Season
(1) Cut off the main power of air conditioner;
(2) Clean the filter screen, indoor and outdoor unit;