36
Technical Information
*Note:
● For preventing cold air, after starting up heat mode, indoor unit
will delay 1~5 minutes to blow air (Actual delay time depends on
indoor ambient temperature).
● Set temperature range from remote controller: 16-30°C(61-
86°F).
● This mode indicator is not available for some models.
● Cooling only unit won't receive heat mode signal. If setting
heat mode with remote controller, press " " button can't start
up the unit.
button
Press this button can set fan speed circularly as: auto (auto),
low ( ), low-medium( ), medium(
), medium-high (
),high(
).
*Note:
● It's low fan speed under dry mode.
● X-FAN function: Holding fan speed button for 2s in cool or
dry mode, the icon " " is displayed and the indoor fan will
continue operation for a few minutes in order to dry the indoor
unit even though you have turned off the unit. After energization,
X-FAN OFF is defaulted. X-FAN is not available in auto, fan or
heat mode.
This function indicates that moisture on evaporator of indoor
unit will be blowed after the unit is stopped to avoid mould.
● Having set X-FAN function on: After turning off the unit by
pressing " " button, indoor fan will continue running for a few
minutes at low speed. In this period, hold fan speed button for
2s to stop indoor fan directly.
Having set X-FAN function off: After turning off the unit by
pressing " " button, the complete unit will be off directly.
button
Under cool or heat mode, press this button to turnto quick cool
or quick heat mode. " " icon isdisplayed on remote controller.
Press this button again to exit turbo function and " " icon will
disappear.
If start this function, the unit will run at super-high fan speed to
cool or heat quickly so that the ambient temperature approaches
the preset temperature as soon as possible.
button
Press "▲" or "▼" button once to increase ordecrease set
temperature 1°C(°F). Holding "▲" or "▼"button, 2s later, set
temperature on remote controller will change quickly. On
releasing button after setting is finished, temperature indicator
on indoor unit will change accordingly. (Temperature can't be
adjusted under auto mode)
When setting TIMER ON, TIMER OFF or CLOCK, press "▲" or
"▼" button to adjust time. (Refer to CLOCK, TIMER ON, TIMER
OFF buttons).
button
Press this button can select left & right swing angle. Fan blow
angle can be selected circularly as below:
no display
(stops at
current position)
*Note
:
● Press this button continuously for more than 2s, themain unit will
swing back and forth from left to right, and then loosen the button,
the unit will stop swinging and present position of guide louver will be
kept immediately.
● Under left and right swing mode, when the status is switched from
off to , if press this button again 2s later, status will switch to
off status directly; if press this button again within 2s, the change
of swing status will also depend on the circulation sequence stated
above.
● The function is only available for some models.
button
Press this button can select up & down swing angle. Fan blow angle
can be selected circularly as below:
no display
(horizontal louvers
stops at current position)
● When selecting "
", air conditioner is blowing fan automatically.
Horizontal louver will automat-ically swing up & down at maximum
angle.
● When selecting "
, , , ,
", air condition-er is blowing fan at
fixed position. Horizontal louver will stop at the fixed position.
● When selecting "
,
,
", air conditioner is blowing fan at fixed
angle. Horizontal louver will send air at the fixed angle.
● Hold "
" button above 2s to set your required swing angle. When
reaching your required angle, release the button.
*Note:
● "
,
,
" may not be available. When air conditioner receives
this signal, the air conditioner will blow fan automatically.
● Press this button continuously for more than 2s, the main unit will
swing back and forth from up to down, and then loosen the button,
the unit present position of guide louver will be kept immediately.
● Under up and down swing mode, when the status is switched from
off to
, if press this button again 2s later,
status will switch
to off status directly; if press this button again within 2s, the change
of swing status will also depend on the circulation sequencestated
above.
button
Press this button, can select Sleep 1( ), Sleep 2 ( ), Sleep 3 ( )
and cancel the Sleep, circulate between these, after electrified, Sleep
Cancel is defaulted.
●Sleep 1 is Sleep mode 1, in Cool modes; sleep status after run for
one hour, the main unit setting temperature will increase 1 , two hours,
setting temperature increased 2 , then the unit will run at this setting
temperature; In Heat mode: sleep status after run for one hour, the
setting temperature will decrease 1 , two hours, setting temperature
will decrease 2 , then the unit will run at this setting temperature.
●Sleep 2 is sleep mode 2, that is air conditioner will run according to
the presetting a group of sleep temperature curve.
●Sleep 3-the sleep curve setting under Sleep mode by DIY;
(1) Under Sleep 3 mode, press “Turbo” button for a long time, remote
controller enters into user individuation sleep setting status, at this
time, the time of remote controller will display “1hour ”, the setting
temperature “88” will display the corresponding temperature of last
setting sleep curve and blink (The first entering will display according
to the initial curve setting value of original factory);