102
Installation and Maintenance
Service Manual
Procedure
Step
Loosen the connection clasps between
vertical louver and bottom case to
remove vertion louver.
Screw off the screws that are locking the
swing motor and take the motor off.
7.Remove vertical louver
8.Remove electric box assy
a
a
b
b
Loosen the connection clasps between
shield cover of electric box sub-assy and
electric box,and then remove the shield
cover of electric box sub-assy.
assy.
Swing motor
Indoor tube
temperature sensor
Main
board
Wiring
terminal
of motor
Wiring
terminal
of stepping
motor
Grounding
Wire binder
Screw
screw
ķ
Cut off the wire binder and pull out
the indoor tube temperature sensor.
ĸ
Screw off one grounding screw.
Ĺ
Remove the wiring terminals of motor
and stepping motor.
ĺ
Remove the electric box assy.
Ļ
Screw off the screws thar are locking
each lead wire.