104
Fault Displays
Models GWH09MB-D3DNA3D & GWH12MB-D3DNA3D
Malfunction
Name
Indoor Unit
Outdoor Unit
A/C Status
Possible Causes
Dual-8
Code
Display
Indicator Display (during blink-
ing, ON 0.5s and OFF 0.5s
Indicator has 3 kinds of display
status and during blinking, ON
0.5s and OFF 0.5s
Operation
Cool
Heating
Yellow
Red
Green
Malfunction
of complete
units current
detection
U5
Off 3S
and blink
13 times
During cooling
and drying oper-
ation, compressor
will stop while
indoor fan will
operate. During
heating operation,
the complete unit
will stop opera-
tion.
Theres circuit
malfunction on
outdoor units
control panel AP1,
please replace the
outdoor units con-
trol panel AP1.
The four-way
valve is abnor-
mal
U7
Off 3S
and blink
20 times
If this malfunction
occurs during
heating operation,
the complete unit
will stop opera-
tion.
1. Supply volt-
age is lower
than AC175V; 2.
Wiring terminal
4V is loosened or
broken; 3. 4V is
damaged, please
replace 4V.
Zero crossing
malfunction
of outdoor
unit
U9
Off 3S
and blink
18 times
During cooling
and drying oper-
ation, compressor
will stop while
indoor fan will
operate. During
heating operation,
the complete unit
will stop opera-
tion.
Replace outdoor
control panel AP1
Frequency
limiting
(power)
L3
Off 3S
and blink
13 times
Compressor
is open-cir-
cuited
L9
Off 1S
and blink
once
The tem-
perature
for turning
on the unit
is reached
LP
Off 1S
and blink
8 times