108
Fault Displays
Models GWH18MC-D3DNA3D & GWH24MD-D3DNA3D
Malfunction
Name
Indoor Unit Displaying Method
Outdoor Unit Display (LED)
A/C Status
Malfunctions
Dual-8
Code
Display
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s
Indicator has 3 kinds of display status and
during blinking, ON 0.5s and OFF 0.5s
Running
LED
Cooling
LED
Heat-
ing
LED
D40/D5
D41/D6
D42/D16 D43/D30
Indoor evap-
orator sensor
circuit open,
short circuit
F2
OFF
3s and
blink
twice
Cooling, dehu-
midifying, ex-
cept the indoor
fan motor is
running, others
will stop to run.
Heating; all
stop running.
1. Room tem-
perature sensor
hasn’t been
connected well
with indoor
units control
panel AP1
(refer to the
wiring diagram
for indoor
unit), 2. Room
temperature
sensor is dam-
aged (please
refer to the
resistance table
of temperature
sensor)
Outdoor am-
bient sensor
circuit open,
circuit short
F3
OFF
3s and
blink 3
times
o
o
¶
n
Cooling, dehu-
midifying, ex-
cept the indoor
fan motor is
running, others
will stop to run.
Heating; all
stop running.
1. Room tem-
perature sensor
hasn't been
connected well
with indoor
units control
panel AP1
(refer to the
wiring diagram
for indoor
unit) 2. Room
temperature
sensor is dam-
aged (please
refer to the
resistance table
of temperature
sensor)