112
Fault Displays
Models GWH18MC-D3DNA3D & GWH24MD-D3DNA3D
Malfunction
Name
Indoor Unit Displaying Method
Outdoor Unit Display (LED)
A/C Status
Malfunc-
tions
Dual-8
Code
Display
Indicator Display (during blink-
ing, ON 0.5s and OFF 0.5s
Indicator has 3 kinds of display status and
during blinking, ON 0.5s and OFF 0.5s
Running
LED
Cooling
LED
Heating
LED
D40/D5
D41/D6
D42/D16 D43/D30
System abnor-
mal
H4
OFF 3S
and blink
4 times
Cooling
dehumidifying
compressor
stop running,
Fan motor
works; Heating
all will stop
Please refer
to trouble-
shooting
IPM protec-
tion
H5
OFF 3S
and blink
times
n
o
n
n
Cooling
dehumidifying
compressor
stop running,
Fan motor
works; Heating
all will stop
Please refer
to trouble-
shooting
PFC protec-
tion
HC
OFF 3S
and blink
6 times
o
n
¶
¶
Compressor
lose steps
H7
OFF 3S
and blink
7 times
o
¶
n
¶
Heating, an-
ti-high temp
declines
H0
OFF 3S
and blink
10 times
n
o
«
¶
Startups fail
Lc
OFF 3S
and blink
11 times
o
¶
o
¶
Compres-
sor current
testing circuit
malfunction
U1
OFF 3S
and blink
13 times
o
¶
n
o
EEPROM
malfunction
EE
OFF 3S
and blink
15 times
o
o
o
n
Capacitor
charge mal-
function
PU
OFF 3S
and blink
17 times
o
n
o
n