117
Fault Displays
Models GWH30LB-D3DNA3E & GWH36LB-D3DNA3E
Malfunction
Name
Indoor Unit
Outdoor Unit
A/C Status
Possible Causes
Dual-8
Code
Display
Indicator Display (during blinking,
ON 0.5s and OFF 0.5s
Indicator has 3 kinds of display
status and during blinking, ON
0.5s and OFF 0.5s
Operation
Cool
Heating
Yellow
Red
Green
Outdoor
ambient
temperature
sensor is
open/short
circuited
F3
Off 3S and
blink 3
times
Off 3S
and blink
6 times
During cooling
and drying oper-
ating, compressor
stops while indoor
fan operates;
During heating
operation, the
complete unit will
stop operation.
Outdoor tempera-
ture sensor hasn’t
been connected
well or is dam-
aged. Please check
it by referring
to the resistance
table for tempera-
ture sensor.
Outdoor
condenser
temperature
sensor is
open/short
circuited
F4
Off 3S and
blink 4
times
Off 3S
and blink
5 times
During cooling
and drying oper-
ating, compressor
stops while indoor
fan operates;
During heating
operation, the
complete unit will
stop operation.
Outdoor tempera-
ture sensor hasn’t
been connected
well or is dam-
aged. Please check
it by referring
to the resistance
table for tempera-
ture sensor.
Outdoor
discharge
temperature
sensor is
open/short
circuited
F5
Off 3S and
blink 5
times
Off 3S
and blink
7 times
During cooling
and drying oper-
ation, compressor
will sop after op-
erating for about
3 mins, while
indoor fan will
operate. During
heating operation,
the complete unit
will stop after op-
erating for about 3
mins.
1. Outdoor
temperature
sensor hasn’t been
connected well
or is damaged.
Please check it by
referring to the
resistance table for
temperature sen-
sor; 2. The head
of temperature
sensor hasn't been
inserted into the
copper tube.
Limit/
decrease
frequency due
to overload
F6
Off 3S and
blink 6
times
Off 3S
and blink
3 times
All loads operate
normally, while
operation frequen-
cy for compressor
is decreased.
Refer to the mal-
function analysis
(overload, high
temperature resis-
tant)