Disassembly of Outdoor Unit
12K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove the screw connecting the electric box
cover with electric box, and then remove electric
box cover. Remove the screws fixing the electric
box sub-assembly; loosen the wire bundle; pull out
the wiring terminals and then pull the electric box
upwards to remove it.
Remove the nuts attaching the blade and then re-
move the axial flow fan.
Remove the four tapping screws fixing the motor;
disconnect the leading wire insert of the motor and
then remove the motor. Remove the two tapping
screws fixing the motor support and then pull the
motor support upwards to remove it.
3. Remove electric box sub-assy
4. Remove axial flow fan and motor