178
Disassembly of Outdoor Unit
12K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
7. Remove the gas and liquid valves and valve support
8. Remove compressor
Remove the screws attached to the gas valve and
unsolder the welding joint between the gas valve
and the air-return pipe to remove the gas valve
(NOTE: Discharge the refrigerant completely
before un-soldering; When un-soldering, wrap
the gas valve with a wet cloth completely to avoid
damage to the valve cause by high temperature).
Remove the screws attached to the liquid valve and
unsolder the welding joint connecting the liquid
valve to the Y-type pipe to remove the liquid valve.
Remove the screws attached to the valve support
with the chassis sub-assembly, then remove the
valve support.
Remove the three nuts on the compressor feet and
then remove the compressor.
7. Remove the gas and liquid valves and valve support
8. Remove compressor