Disassembly of Outdoor Unit
36K 240 volt unit shown, other models may vary slightly
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove the tapping screws fixing the motor, pull out
the pin of leading wire for motor and then remove
the motor.
Remove the tapping screws fixing the motor support,
pull it upwards and then remove the motor support.
11. Remove 4-way valve
10. Remove motor and motor support
Unsolder the pipeline between compressor, con-
denser, gas and liquid valve, and then remove the
4-way valve (Note: Release all refrigerant before
un-soldering).