9
Note: The manufacturer reserves the right to modify the design and/or change the specifications without notice. Please
refer to specific installation manual for current information.
Physical & Electrical Data, cont.
Model
GWH30LB-D3DNA3E
GWH36LB-D3DNA3E
System Type
Heat Pump
Power Supply
208-230v / 60Hz
208-230V / 60Hz
Rated Current Cooling
Amps
12.1
15.9
Rated Current Heating
Amps
12.5
15.5
System Performance
Cooling Cap (Min/Max)
Btu/h
28,000 (9,500-30,000))
33,600 (7,400-36,000)
Heating Cap (Min/Max)
Btu/h
28,400 (10,000-33,000)
34,600 (15,000-36,000)
Operating Range - Cooing
deg F
25 - 115
25 - 115
Operating Range - Heating
deg F
5 - 65
5 - 65
System Specifications
Compressor Type
DC Inverter-driven Twin Rotary
Sound Level
db
50
52
Net/Gross Weight Indoor
lb
22 / 29
22 / 29
Net/Gross Weight Outdoor
lb
75 / 90
88 / 97
Condenser Coil Type
Gold Fin Coated
Refrigerant/Charge
oz
R410a / 84.7
R410a / 91.7
Line Set Size Liq. - Suction
1/4” - 5/8”
1/4” - 5/8”
Pre-Charged Lineset Ft.
Feet
25
25
Additional Refrigerant
charge/additional feet
oz
0.5
0.5
Max. Total Piping Length
Feet
100
100
Max. Elevation
Feet
33
33
MCA
Amps
20
24
MOCP/Breaker Size
Amps
30
35
Wire Size to Outdoor Unit, #
of Wires per Local Code
awg
10
8
Wire Size and # of Conduc-
tors from Indoor to Outdoor
unit
14awg/4c