1)On/Off
The on-off state will change with each button press.
2)Mode Selection
Press the “Mode” button to change from Auto, Cool, Dry, Fan or Heat Pump
3)Temperature Setting
Each time you press the “TEMP+” or “TEMP-” button the temperature setting will change by 10 F. The temperature range
is 610 F - 860 F. In Auto Mode this button will not function.
4)Time Switch
The unit will stop and start by setting the Timer on the remote controller.
5)Energy Savings Mode
(Press Temp & Clock simultaneously, display will indicate “SE”)
In heating mode, refer to the Cold Air Prevention explained in the (3)Heating Mode process .
In cooling mode, the fan speed will adjust according to the fan speed curve below:
System Operation 18,000/24,000 btuh Models, cont.
Other Controls
Product Introduction
T
amb.
T
preset
+ 30 F
T
preset
+ 10 F
Fan Speed
Turbo
High
Med.
Low
880 F