98
4. Assemble unit
Assemble the unit in the reverse
procedures of disassembly.
36k
Disassembly and Assembly of external casing
Remark :
Step
Illustration
Handling Instruction
1. Remove external casing
1. Remove the top cover and handle;
2. Remove the grille, outer case and right
side plate.
2. Remove motor
1. Remove the blade nut and then remove
the blade;
2. Remove the motor from motor support.
3. Remove gas liquid separator
1. Discharge the refrigerant inside the
pipeline and recycle the refrigerant during
discharging;
2. Unsolder the 4-way valve assy from gas
liquid separator;
3. Remove the gas liquid
separator.