U-MATCH SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL
62
2.4 Dimension Data
Figure 3-2-2
Table 3-2-1
Unit: mm (inch)
Item
Model
A
B
C
D
E
UMAT18HP230V1BO
955(37-5/8)
395(15-5/8)
700(27-1/2)
560(22)
360(14-1/8)
UMAT24HP230V1BO
980(38-5/8)
425(16-3/4)
790(31-1/8)
610(24)
390(15-1/2)
UMAT30HP230V1BO
UMAT36HP230V1BO
1105(43-5/8)
440(17-3/8)
1100(43-1/4)
630(24-7/8)
400(15-3/4)
UMAT42HP230V1BO
960(37-3/4)
410(16-1/4)
1350(53-1/8)
570(22-1/2)
375(14-3/4)
UMAT48HP230V1BO
3 REFRIGERATION PIPING WORK
3.1 Refrigeration Piping Work Procedures and Caution in
Connecting
3.1.1 Flare Processing
(1) Cut the connection pipe with the pipe cutter and remove the burrs.
(2) Hold the pipe downward to prevent cuttings from entering the pipe.
(3) Remove the flare nuts at the stop valve of the outdoor unit and inside the accessory bag of the
indoor unit, then insert them to the connection pipe, after that, flare the connection pipe with a flaring
tool.
(4) Check if the flare part is spread evenly and there are no cracks (see Figure 3-2-3).
Figure 3-2-3