background image

CE INFORMATION

ACTION TYPE: IB
POLLUTION SITUATION: NORMAL 

CLASS 

2

INSULATION:

:MICRO-DISCONNECTION LIVE

POLE ONLY

MANUAL OVERRIDE

SUMMER TIME SETTING

TIMER COUNTDOWN 

FUNCTION

1. Timer has a 100 hour countdown feature i.e. the

timer can be set to any period from 1 minute to 

100 hours and will countdown in the ON state 

and turn OFF at the end of the countdown 

period.

2. Press the Y button then use the + or - button to 

select the “down” icon on the right hand side 

of the display, press Y again to enter the count

down mode.

3. Use the + or - button to adjust the hours and 

press Y to confirm. minutes will flash.

4. Use the + or - button to adjust the minutes and 

press Y to confirm and complete the 

countdown time setting.

5. Press the N button to start the countdown.

6. Output switched to ON during the countdown 

period.

7. Press the N button to pause the countdown 

(output switched to OFF)

8. To resume countdown simply press the N button

again.

9. Press and hold the N button for more than 3 

seconds to exit the countdown function.

1. When in normal clock mode, pressing the N 

button will scroll through the following switching

options.

• ALWAYS ON - timer is permanently ON.

PROG - timer is in programme ON mode, 

will switch off at the next programme OFF time.

• ALWAYS OFF - timer is permanently OFF.

• PROG       - timer is in programme OFF mode, 

will switch on at the next programme ON time.

1. Press the Y button, then use the + or - buttons to

scroll through to “summer” (flashing).

2. Press the Y button again to access the summer 

time setting.

3. Press the + or - button to change between 

summer on or off.

4. Press Y to confirm summer setting, time will 

advance 1 hour.

5. A “SUMMER” icon will appear in the display.

6. Use the same procedure to remove the 

“SUMMER” icon when reverting to GMT in the 

winter.

TECHNICAL INFORMATION

RESET

READING YOUR 

PROGRAMMED TIMES

Pressing the reset button R with a pencil or similar

will reset all programmed times and set time of

day to zero.

1. Press Y button twice to enter programme 

mode.

2. Press the + or - buttons to scroll through the 24 

ON/OFF programmes to check settings.

3. Press the N button to exit and revert to clock 

mode.

3. Default is programme 01 ON, this can be 

changed if required by pr or - button to 

scroll through the 24 ON/OFF programmes as 

required, pressing the Y will confirm the 

programme.

4. Press the Y button to confirm programme 01 

ON, hours will flash.

5. Use the + or - button to adjust the hours and 

press Y to confirm, minutes will flash.

6. Use the + or - button to adjust the minutes and 

press Y to confirm, days will flash.

7. Apart from individual days of the week, the 

following day combinations of multiple day 

blocks can be selected by pressing the + or - 

buttons.

• Monday to Sunday

• Monday to Friday

• Saturday to Sunday

• Monday to Saturday

•  Wed Friday

• T Th Saturday

•  T Wednesday

•  Th  Saturday

8. Select day or day block as required and press

the Y  button to confirm.

9. Press the + button, this will select the 

programme 01 OFF, press Y to confirm.

10.Follow 4 to 7 above to set the 01 OFF 

programme (day or day block must be the 

same as programme ON).

11.If no more programmes are required, press the 

N button to exit.

12.If more programmes are required follow step 3.

13.To cancel a programme once set, press and 

hold the N button for more than 3 seconds 

when the desired programme number is 

flashing i.e. to cancel programme 01 ON, press 

the Y button twice and hold the N button down

for more than 3 seconds to delete. Pressing the 

+ button again will select 01 OFF.

14.Repeat 13 to delete 01 OFF. This procedure can 

be repeated to delete any of the 24 

programmes.

Issu

e n

o: 

70

52

14

WEST  ROAD  .  HARLOW

ESSEX . CM20 2BG . UK

info@greenbrook.co.uk

www.greenbrook.co.uk

GUARANTEE

Your GreenBrook 7 Day Electronic Timer 

is guaranteed for 1 year from 

the date of purchase. 

This is in addition to your statutory rights.

PLEASE KEEP THESE INSTRUCTIONS 

SAFE FOR FUTURE REFERENCE

Switching Capacity:

230V AC, 16A resistive, 

2A Inductive

Ambient Temperature:

-10°C to + 55°C

Battery Back Up:

150 hours

Memory Location:

24

Shortest Switching Time: 1 minute
Wattage:

3000W

Conforms To:

BS EN 60730-1, 

BS EN 60730-2-7

T106A-C Ins Feb 18.qxp_Layout 1  23/02/2018  14:06  Page 2