Pellet burner GP 45 IV 21
The auger tilt angle change leads to change in the fuel consumption and
respectively to the burner’s heating output:
- decreasing the auger tilt angle leads to increased fuel consumption,
respectively to increased heating output;
- increasing the auger tilt angle leads to decreased fuel consumption,
respectively to decreased heating output.
Schematic view for installation of the fuel transport auger is presented on Figure 5.5.
Figure 5.5. Schematic view for installation and positioning of the fuel transport auger.
The auger on the above figure is equipped with support bar, which is additional
option (not standard equipped) to the burner delivery kit. The tilt angle between
the auger axis and the horizontal plane has to be 45
o
.
The fuel transport auger can be mounted to a fuel hopper that provides capacity up to 650 kg
of wood pellets (Figure 5.6).
45
о
Fuel hopper
“BP”