Step 4 - Install a protective cap for the AC cable at the end of the AC cable.
Step 5 - Connect microinverters to photovoltaic modules.
WARNING:
When the DC cables are connected the microinverter should
immediately flash one quick red and three times the green LED. This will
happen as soon as the cables are connected which will show that the
microinverter is working properly.
This entire check function will start and stop within 5 seconds of connecting the
unit, so keep an eye out for these lights when connecting the DC cables.
Microinverter System User Manual
To operate a microinverter PV system:
1 Turn on the AC breaker on each AC circuit of the microinverter.
2. turn on the main AC breaker from the grid. Your system will begin generating
power after a minute of waiting.
-9-